Release 10.0.49.58 (September 2026)

Prev Next

Find information on Release 10.0.49.58 (September 2026) of STAEDEAN Life Sciences for Microsoft Dynamics 365 Finance & Supply Chain Management.

Version information:

Product

Latest version

Minimum version

Latest validated version

Planned next

STAEDEAN Life Sciences

10.0.49.58

D365 F&SCM 10.0.49

D365 F&SCM 10.0.49

January 2027

STAEDEAN Life Sciences Weighing and Dispensing module

18.00 R6 (484)

D365 F&SCM 10.0.49

STAEDEAN Life Sciences 10.0.49.58

D365 F&SCM 10.0.49

January 2027

What’s new

New features in Release 10.0.49.58 (September 2026) of STAEDEAN Life Sciences.

Module

Feature Name

Description

Life Sciences Supply Chain Management

Custom batch job for sub-batch registration

You can now run sub-batch creation and confirmation as a background batch job. Users continue with other work while the system creates and registers large numbers of sub-batches. This removes the time-outs that happened during manual registration of large volumes.

Life Sciences Supply Chain Management

Sub-batch synchronization in intercompany orders

The system now synchronizes sub-batch information between intercompany orders. Sub-batch details stay intact, and sub-batch uniqueness is kept for each legal entity.

Life Sciences Warehouse Management

Sub-batch receipt in intercompany orders via mobile device

You can now receive intercompany purchase orders through the mobile device without scanning each sub-batch number.

Life Sciences Warehouse Management

Sub-batch creation method on the mobile device

You can now set the preferred sub-batch creation method for each Mobile device menu item. Based on the setting, the system prompts the operator to enter either the quantity of each sub-batch, or the total number of sub-batches. This reduces data-entry errors during purchase order registration and report as finished.

What's changed

Changed features in Release 10.0.49.58 (September 2026) of STAEDEAN Life Sciences. Each enhancement provides an incremental improvement to existing functionality.

Module

Feature Name

Description

STAEDEAN Common library

STAEDEAN Common library

This release includes STAEDEAN Common Library, version 65. These new features are available:

  • Download a license package: Skip maintenance mode and download the latest license package directly from the STAEDEAN Solution Management workspace.

  • Download a unified package: Quickly find and download the right unified package for your installed solution, compliant with the N-3 support policy.

See also: STAEDEAN Common Library.

Life Sciences Warehouse Management

Total sub-batch quantity on report as finished

You can now delete sub-batches directly from the Registration lines page on the mobile device.

Life Sciences Supply Chain Management

Approved customer check in the item change approval workflow

The item change approval workflow now integrates with the Microsoft Approved customer list check method.

Life Sciences Quality Control & Assurance

Test and outcome translations on the Certificate of analysis

You can now define translations for tests and variable outcomes and print them on the Certificate of analysis. You can also link a text specification to a test to describe the accepted outcome and print its translation on the report. The Specification field is now available in the Test group test assignment entity.

Life Sciences Warehouse Management

Split work across several pick work lines

The system now splits work automatically, or optionally, across several pick work lines. This covers cases where separate pick lines exist for the same item and batch, for example from different sales orders or sales order lines.

Life Sciences Supply Chain Management

Approved by traceability for formula approval

The formula approval release for production now follows the Microsoft standard behavior. The system displays and traces the Approved by field, and shows a confirmation message. When the Block editing from approval parameter is enabled, you cannot change the approver.

Life Sciences Cloud Compliance Suite

Refresh fields and document renaming

A new Refresh fields button updates the fields for the selected tables only. You no longer repopulate all related tables and remove the ones you do not need. The Configuration specification document is renamed to Configuration evidence document.

Life Sciences Quality Control & Assurance

Test result data entry alignment with Microsoft Advanced quality management

The Test result data entry page is now aligned with the quality order lines. The system shows the Result entered field when the Microsoft Advanced quality management feature is disabled, and the Test results exist field when it is enabled. You can add the new Advanced quality management fields to the page through personalization.

Life Sciences Quality Control & Assurance

Decimal precision in Quick result entry

A new Hide standard specifications parameter controls which specification fields appear in Quick result entry. The Min, Max, and Standard fields now show the correct decimals for each line, in Quick result entry and on the Overview tab. Exports to Excel now keep the full decimal precision.

Life Sciences Warehouse Management

Warehouse Management app messages

Life Sciences messages and confirmation messages now match the Microsoft Warehouse Management app version 4. The app shows the message text directly, not only as a pop-up. Operators get a consistent experience across the app.

Life Sciences Quality Control & Assurance

Quality inquiries enhancement

The Test result data entry page now includes several new fields and usability improvements that make it easier to filter and export quality order test results. The new Test description field shows the full test description instead of only the Test ID. The new Result value field shows the numerical result (average, minimum, or maximum, according to the Test value determination defined for the test group line). The new Outcome result field shows the qualitative result for tests of type Option. The pass or fail result is now filterable and exportable, and the Test method name, its description, and the Test results exist field are now shown and filterable.

Life Sciences Warehouse Management

Unpick destination location on the mobile device

A new parameter on the Mobile device menu item controls the reduce picked quantity activity for sales and transfer. The put location can follow the Inventory movement location directives, or stay blank. When it stays blank, the system prompts the operator to scan the destination location.

Life Sciences Warehouse Management

Work report layout

You can now configure the Work report layout. You can print the header on the first page only, print the report in landscape, and add a column for batch attributes. A parameter controls whether the Life Sciences extension applies. When you disable it, the system uses the standard or custom layout.

Life Sciences Quality Control & Assurance

Quality associations by intended use

You can now use the Intended use code as a criterion for quality associations of type Return, Transfer, and Project. Before, this criterion was available only for Production and Purchase quality orders.

Life Sciences Weighing and Dispensing

Weighing and Dispensing application

Enhanced the centralized update process for the Weighing and Dispensing application client. The process automatically deploys client updates across all dispensing workstations, eliminating manual workstation-by-workstation installation and reducing maintenance effort and downtime.

Life Sciences Quality Control & Assurance

Print rounded specifications and results on the Certificate of analysis

You can now print specifications and results on the Certificate of analysis with fewer decimals than the decimal precision defined for the test. You define rounding rules for specifications and results on the test group and quality order lines, using the Enable rounding option and a Relevant-decimal setting.

Life Sciences Supply Chain Management

Sub batch registration performance

Improved the performance of the sub-batch registration process to address processing delays during high-volume sub-batch creation. The optimization introduces SQL indexing on the sub-batch tables, reduces validation overhead, refines database logging, and enables asynchronous sub-batch generation and registration. There is no functional change to the process.

Bug fixes

Bug fixes in Release 10.0.49.58 (September 2026) of STAEDEAN Life Sciences.

Module

Bug ID

Bug Name

Description

Life Sciences Supply Chain Management

49261

Approved manufacturer check error for approved manufacturer

The system failed to record the manufacturer name in the Batches table, which triggered the approved manufacturer error when the item’s Approved manufacturer check method was set to Not allowed and the manufacturer’s vendor number was long.

Life Sciences Quality Control & Assurance

48937

It is not possible to create a new test group version if the previous version is "Not submitted"

When the previous test group version had the Not submitted status, the system blocked you from creating a new version. You can now create a new test group version even when the previous version is in the Not submitted status.

Life Sciences Warehouse Management

47833

It is not possible to delete newly created warehouses

The system prevented you from deleting a warehouse that you had just created with Use warehouse management processes enabled. You can now delete newly created warehouses.

Life Sciences Warehouse Management

47020

Multiple lines are incorrectly displayed in the On-hand inquiry when no dimensions are displayed

The On-hand inquiry showed duplicate lines for the same stock when no dimensions were displayed, which made the on-hand quantity hard to read. The On-hand inquiry no longer shows duplicate lines when no dimensions are displayed.

Life Sciences Warehouse Management

49238

Not possible to unpick when a shipment contains multiple batches

When you used the Reduce picked quantity process through the Warehouse Management mobile app for a sales shipment containing multiple batches and license plates, the system could select a different license plate, use the wrong batch number, or display the “No on-hand inventory has been selected” error. Other methods of reversing a pick were not affected. The mobile app process now correctly reduces the picked quantity for the selected license plate.

Life Sciences Supply Chain Management

49535

Sales order confirmations are always printed with same layout when using the 'Original preview' and 'Copy preview' functionality

When you used the Original preview and Copy preview options, sales order confirmations were always printed with the same layout instead of the layout configured in Print management. Sales order confirmations now use the correct layout for the Original preview and Copy preview functions.

Life Sciences Supply Chain Management

49570

Sales order packing slip are always printed with same layout when using the 'Original preview' and 'Copy preview' functionality

When you used the Original preview and Copy preview options, sales order packing slips were always printed with the same layout instead of the configured layout. Sales order packing slips now use the correct layout for the Original preview and Copy preview functions.

Life Sciences Warehouse Management

49115

Shipment type is not printing actual value based on Label layout configuration

When a license plate label layout used the Shipment type field, the label printed the internal numeric value instead of the actual shipment type ID, such as Air. To display the correct value, update the label layout to use WHSShipmentTable_1.BPHdisplayShipmentTypeId() from Methods instead of WHSShipmentTable_1.BPHShipmentType from Fields.

Life Sciences Quality Control & Assurance

48915

The Min/Max (Result range) fields should be non editable in the Quality order line for test type "Option"

On quality order lines for a test of type Option, the Min and Max (result range) fields were editable, although they carry no meaning for that test type and should be read-only. The Min and Max result range fields are now read-only on quality order lines for tests of type Option.

Life Sciences Weighing and Dispensing

47898

W&D - Rejected line does not displayed the weighed quantity

When you rejected a weighing operation, the Weighing and dispensing application set the order line Status to Cancelled but did not update the quantity field with the rejected (weighed) quantity. A rejected line now shows the weighed quantity.

Life Sciences Supply Chain Management

47470

When using the "Split" functionality for batch orders, the "Inherit manufacturing date for end item" radio button is not inherited in the new batch order

When you used the Split function to divide a batch order, the new batch order did not inherit the Inherit manufacturing date for end item setting from the original order. The new batch order now inherits the Inherit manufacturing date for end item setting when you split a batch order.

Life Sciences Quality Control & Assurance

46941

Overlapping active test group versions could be saved when modifying validity dates

When you modified the From date and To date of a test group, the system saved the change even when it left two test group versions active with overlapping date ranges. The system now prevents validity dates that would create two active, overlapping test group versions.

Life Sciences Quality Control & Assurance

47774

Test result outcomes are not recalculated after copying results from a quality order

When you used the Copy test results function, the system copied the test outcomes together with the results, regardless of the test criteria of the target quality order. The outcomes are now recalculated based on the target quality order's test criteria.

Life Sciences Supply Chain Management

49060

Reservation logic not overwritten for active ingredients in a phantom item when Skip batch balancing is enabled

When Skip batch balancing was enabled, the system did not override the Reservation field on the batch order formula line for an active ingredient inherited from a phantom item’s formula during estimation. The field remained set to Manual, and the ingredient was not automatically reserved. The system now applies the batch order’s reservation value to active ingredients in both the main and phantom formulas, unless the item model group overrides it, and reserves the ingredients according to that setting.

Life Sciences Quality Control & Assurance

49305

Quality order with a single optional-test line failed instead of passing

A quality order that contained a single quality order line with an optional test failed instead of passing, even though the Results entered option was selected for that optional test. The quality order now returns a Pass outcome in this scenario.

Life Sciences Warehouse Management

49650

Batch cannot be received or overridden during Goods in transit receipt

During a Goods in transit receipt of a purchase order (with Goods in transit management enabled), you could not receive or override the batch number. You can now receive or override the batch during the Goods in transit receipt.

Life Sciences Quality Control & Assurance

49739

Test specification with a negative Max is not allowed when Min is set to "No limit"

When the Min result range was set to No limit, the system defaulted the minimum value to zero, so a specification with a negative Max and Standard returned an error. You can now define a test specification with a negative Max value when the Min result range is set to No limit.

Life Sciences Supply Chain Management

60020

Automatic batch balancing uses more than two decimals, causing an "Active quantity of 0.00 remains to be filled" error

When releasing a dispensing order after automatic batch balancing, a small remaining active ingredient quantity, such as 0.00X, could be displayed as 0.00 and incorrectly trigger the error “Active quantity of 0.00 remains to be filled for Lot ID %,” preventing the release. The validation now suppresses this error when the remaining quantity rounds to 0.00 and allows the dispensing order to be released. Automatic batch-balancing calculations continue to use the same full precision and standard calculation method.

Life Sciences Quality Control & Assurance

60068

Result value (Rounded) and Analysis type not displayed in Quick result entry

The Result value (Rounded) field in Quick results entry now correctly displays the result rounded according to the Relevant decimals defined on the quality order line when rounding is enabled. The Analysis type field now inherits and displays the correct value assigned to the test and remains read-only.

Life Sciences Weighing and Dispensing

42271

Dispensing order lines lock incorrectly removed leading to WorkOrderOperation entity locked in the W&D application

(W&D Application) When a user started processing a dispensing order line in the W&D application, the system correctly locked the line to prevent another user from processing it at the same time. However, the lock remained after the dispensing operation was completed or canceled, causing the next user who selected the same line to receive the “The selected Entity is unavailable” error. The system now removes the lock when the operation is Completed or Canceled while keeping the line locked during active processing.

Life Sciences Warehouse Management

60043

Lines are visible in the Storage Condition form for newly created Location's

When opening the Storage conditions form for a newly created location (Warehouse management > Setup > Warehouse > Locations) where no storage condition is approved or activated, the form now opens blank instead of incorrectly displaying Storage condition variable lines at line level.

Life Sciences Warehouse Management

60379

Batch number is displayed twice in movement by template via mobile device

During Movement by template on a mobile device, the batch number is now displayed only once instead of twice when the Mobile device menu item is configured with the Full LP movement policy set to Use specification for single item movement.

Life Sciences Weighing and Dispensing

60259

Material type groups are not taken into consideration by the cleaning rules during cleaning operation creation

The Cleaning rules (Inventory management > Setup > Cleaning > Cleaning rule) now consider the Material type group when selecting the appropriate rule for creating a cleaning operation.

Life Sciences Weighing and Dispensing

47314

W&D - Cannot weigh expired sub batch

Expired sub batches can now be weighed in the Weighing and Dispensing application when the Expired sub batch option is enabled in D365. When an expired sub batch is scanned, the system now displays a warning message and requires second-person verification to complete the weighing, instead of returning a blocking error.

Life Sciences Weighing and Dispensing

61955

Reduce picked quantity form does not display all picked sub-batches

The Reduce picked quantity form now displays all picked sub-batches. After picking multiple sub-batches in a transfer order pick, all selected sub-batches are correctly listed and available for quantity adjustments.

Removed or deprecated features

Removed or deprecated features in Release 10.0.49.58 (September 2026) of STAEDEAN Life Sciences:

  • A removed feature is no longer available in the product.

  • A deprecated feature is not in active development and may be removed in a future update.

Before any feature is removed from the product, the deprecation notice is announced in the release notes.

Feature: Use advanced inquiry layout parameter for advanced inquiries

Field

Value

Module

Life Sciences Warehouse Management

Reason for deprecation or removal

The system shows the advanced layout by default, so the parameter is no longer needed.

Replaced by another feature?

Yes. The advanced layout is the default.

Product areas affected

Mobile device menu items (advanced location, item, license plate, batch, and sub-batch inquiries)

Status

Removed

The Use advanced inquiry layout radio button is removed from the Mobile device menu items page for the advanced inquiry activity codes. The system shows the advanced layout by default.

Feature: Use advanced layout parameter for reprint label

Field

Value

Module

Life Sciences Warehouse Management

Reason for deprecation or removal

The system shows the advanced layout by default.

Replaced by another feature?

Yes. The advanced layout is the default.

Product areas affected

Mobile device menu items (Reprint product label)

Status

Removed

The Use advanced layout and Records per page fields are removed from the Mobile device menu items page for the Reprint product label activity code. The system shows the advanced layout by default.

Feature: Use advanced registration layout parameter for registration lines

Field

Value

Module

Life Sciences Warehouse Management

Reason for deprecation or removal

The system shows the advanced layout by default.

Replaced by another feature?

Yes. The advanced layout is the default.

Product areas affected

Mobile device menu items (Work mode; advanced report as finished, receiving, and put-away activity codes)

Status

Removed

The Use advanced layout and Records per page fields are removed from the Mobile device menu items page for the Reprint product label activity code. The system shows the advanced layout by default.

Feature: LSS Approved customer check method

Field

Value

Module

Life Sciences Warehouse Management

Reason for deprecation or removal

The Microsoft Approved customer list check method replaces it.

Replaced by another feature?

Yes. Microsoft Approved customer list check method.

Product areas affected

Item approval workflow and item check methods

Status

Deprecated

Recommended actions for Release 10.0.49.58 (September 2026) of STAEDEAN Life Sciences.

  1. Disable the LSS Approved customer configuration key. This prevents a duplicate check method when you adopt the Microsoft Approved customer list check method. The LSS Approved customer check method is deprecated.

Appendix

1. STAEDEAN solution integrations

The following STAEDEAN solutions integrated with STAEDEAN Life Sciences are re‑validated through a structured process including preparation, risk and impact assessment, integrated testing, and final verification, ensuring sustained applicability to Life Sciences processes:

  • Connectivity Studio 10.0.49.74

  • Security and Compliance Studio 10.0.49.55

  • Data Entry Workflow 10.0.49.30

  • Data Quality Studio 10.0.49.20

  • Master Data Management 10.0.49.74

  • Electronic Data Interchange 10.0.49.74

2. Third party libraries

The following table lists the third-party components and versions included in this Life Sciences release. All components were reviewed for security vulnerabilities on 24 August 2026; no issues were identified.

Component

Version

Application server

18.00 R6

AWMAccountEnabledAADAPI

1.0.0

Crystal Reports for .NET Framework

13.0.4000.0

DckHostConnectorLibrary

18

DckPrintController

18

Debenu PDF library

14.11

Desktop client

18.00 R6

DevExpress VCL

23.2.6

Dispensing client

18.00 R6

Eurekalog

7.6.6.0

FastMM

n.d.

IconFontsImageList VCL

n.d.

Konopka VCL controls (raize)

6.2.2

Korzh Simple Query

4.17

License monitor

18.00 R6

License server

18.00 R6

Microsoft Edge WebView2

n.d.

Microsoft.Graph

3.19.0

Microsoft.Graph.Core

1.22.0

Microsoft.Identity.Client

4.45.0.0

Microsoft.IdentityModel.Abstractions

6.18.0.0

Microsoft.IdentityModel.Clients.ActiveDirectory

5.2.9.0

Png components

n.d.

QuickLib-2.3.1

n.d.

QuickLogger-1.46

n.d.

sapnco

3.0.0.42

ScaleRichView

15

Smimport suite

2.67

Spring Framework for Delphi

n.d.

TeeChart Pro

2019

TMS Scripter

7.7

TMS VCL UI pack

8.1.4.0

TurboPack AsyncPro

n.d.

TurboPack OnGuard

n.d.

TurboPack Orpheus

n.d.

VirtulaTreeView

n.d.

WebView4Delphi

n.d.

WiRL-Master

n.d.