--- title: "Result range" slug: "result-range" tags: ["Life Sciences", "Quality Control and Assurance"] updated: 2026-06-25T10:24:07Z published: 2026-06-25T10:24:07Z canonical: "docs.staedean.com/result-range" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.staedean.com/llms.txt > Use this file to discover all available pages before exploring further. # Result range Test specifications like “Each result should be greater than or equal to the minimum value” require users to set up only one limit (in this example, the minimum). Life Sciences Quality Control & Assurance allows users to define only one limit (minimum or maximum) for a specific test. The setup consists of the following: - Setting the limit that is not used (for example, **Min**) to **No limit**. - Indicating the applicable range for the valid limit, for example, **Less than or equal to**. the result range functionality is integrated with Microsoft’s [**Quick result entry**](https://learn.microsoft.com/en-us/dynamics365/supply-chain/inventory/quality-quick-results-entry) form, allowing to display specifications and results in the new interface according to the defined decimal precision. #### Example The lab analyst is adding a test group line for a test with the following specification: “Results should be less than or equal to 15”. The test group line should be set up as follows: - **Result range:** - **Min:** **No limit** - **Max:** **<=** - Test measurement value: - **Standard:** “12” - **Min:** disabled - **Max:** “15” ## Related - [Test groups](/test-groups.md) - [Quality control setup](/quality-control-setup.md)